LQ-Box type (module)
LQ
Economy and steadily: refrigeration compressor adopts the imported famous brand totally enclosed type compressor.
it is of small noise, high efficiency, and it contains the efficient heat exchange copper tube, import refrigeration valve parts.
It makes the chiller to be used for a long time and run steadily.
Easy operation: the daily operation of the chiller is focus on the control panel, and easy to operate,.
you can to set it by the import SEIMENS PLC,it can be controlled accurately, also it can offer the froze water from 5℃to 20℃。
High efficient and flexible:the air cooling chiller does not need to configure the cooling tower and the pump,
it can continue to provide the frozen water. And there is the wheel at the bottom of the small equipment,
you can adjust the location by yourself, also it contains many groups of frozen water interface,flexible and convenient.
Safe running: the chiller has these function of air switch, thermal overload protection,
high and low pressure protection,power protection,water tank protection,
delay control and automatic reset operation besides the compressor protection,
it make sure that the chiller will run safely.
Modular units except the above characteristics,but also has the follow advantages:
Many units can run and control independently,each compressor according to the operation condition,
start or stop in turn,small impact on the grid,and running stability,effectiveness of small fluctuations.
Many sets of independent refrigeration system in units fault will not affect the normal work of the other units,
so the guarantee of safety performance is high.Compressor can turn on or off freely according to the cold quantity changes,
turning off the power of the other units,so as to achieve energy saving purpose.
Economy and steadily: refrigeration compressor adopts the imported famous brand totally enclosed type compressor.
it is of small noise, high efficiency, and it contains the efficient heat exchange copper tube, import refrigeration valve parts.
It makes the chiller to be used for a long time and run steadily.
Easy operation: the daily operation of the chiller is focus on the control panel, and easy to operate,.
you can to set it by the import SEIMENS PLC,it can be controlled accurately, also it can offer the froze water from 5℃to 20℃。
High efficient and flexible:the air cooling chiller does not need to configure the cooling tower and the pump,
it can continue to provide the frozen water. And there is the wheel at the bottom of the small equipment,
you can adjust the location by yourself, also it contains many groups of frozen water interface,flexible and convenient.
Safe running: the chiller has these function of air switch, thermal overload protection,
high and low pressure protection,power protection,water tank protection,
delay control and automatic reset operation besides the compressor protection,
it make sure that the chiller will run safely.
Modular units except the above characteristics,but also has the follow advantages:
Many units can run and control independently,each compressor according to the operation condition,
start or stop in turn,small impact on the grid,and running stability,effectiveness of small fluctuations.
Many sets of independent refrigeration system in units fault will not affect the normal work of the other units,
so the guarantee of safety performance is high.Compressor can turn on or off freely according to the cold quantity changes,
turning off the power of the other units,so as to achieve energy saving purpose.
Model | STSW | 18 | 22.5 | 30 | 37.5 | 48 | 52.5 | 62.5 | 80 | 112.5 | 144 | 180 | 208 | 260 | 400 | 500 |
Power For Compressor | Low frequency kw | 4.50 | 5.63 | 7.5 | 9.38 | 12 | 9.38 | 9.38 | 15 | 9.38 | 12 | 15 | 12 | 23.5 | 25.5 | 25.5 |
High frequency kw | 13.50 | 16.88 | 22.50 | 28.13 | 36 | 39.38 | 46.88 | 60 | 84.38 | 108 | 135 | 156 | 159.3 | 271.3 | 322.3 | |
Cooling Capacity | Low frequency kw | 22.71 | 28.38 | 37.05 | 47.3 | 60.56 | 47.3 | 47.3 | 75.7 | 47.3 | 60.56 | 75.7 | 60.56 | 103.1 | 103.1 | 103.1 |
High frequency kw | 68.13 | 85.16 | 113.55 | 141.93 | 181.68 | 198.71 | 236.56 | 302.8 | 425.8 | 545.09 | 681.3 | 787.28 | 937 | 1529 | 1825.6 | |
Refrigerant | R410a | |||||||||||||||
Voltage | 3P 380V 50HZ/N/PE | |||||||||||||||
Protection Function | Refrigeration high and low pressure protection, water system fault protection, antifreeze protection, compressor overheating overload protection, etc. | |||||||||||||||
Power For Cooling Water Pump | kw | 3.0 | 3.0 | 4.0 | 4.0 | 4.0 | 5.5 | 5.5 | 7.5 | 7.5 | 11 | 11 | 11 | 18.5 | 22 | 37 |
Chilled Water Flow | m³/h | 15 | 18 | 25 | 30 | 40 | 40 | 50 | 60 | 80 | 100 | 120 | 150 | 185 | 265 | 320 |
Chilled Water Tube | DN | 50 | 50 | 65 | 65 | 80 | 80 | 80 | 100 | 100 | 100 | 125 | 125 | 150 | 200 | 225 |
Water Flow | m³/h | 18 | 22.5 | 30 | 37.5 | 48 | 52.5 | 62.5 | 80 | 110 | 140 | 180 | 200 | 230 | 350 | 450 |
Water Tube Diameter | DN | 50 | 50 | 65 | 65 | 65 | 80 | 80 | 80 | 80 | 125 | 125 | 150 | 150 | 250 | 250 |
Dimension | L | 1800 | 1800 | 2200 | 2200 | 2400 | 2400 | 2400 | 3500 | 3500 | 3500 | 5300 | 5300 | 5300 | 5800 | 6500 |
W | 1200 | 1200 | 1200 | 1200 | 1400 | 1400 | 1400 | 1660 | 1660 | 1660 | 220 | 2200 | 2200 | 2200 | 2350 | |
H | 1300 | 1300 | 1500 | 1500 | 1320 | 1320 | 1320 | 1500 | 1500 | 1500 | 1800 | 1800 | 1800 | 2200 | 2200 | |
Weight | kg | 550 | 550 | 950 | 950 | 1200 | 1200 | 1200 | 1760 | 1950 | 2200 | 2500 | 2500 | 2500 | 3800 | 4200 |
Model | STSW | 18 | 22.5 | 30 | 37.5 | 48 | 52.5 | 62.5 | 80 | 112.5 | 144 | 180 | 208 | 260 | 400 | 500 |
Power For Compressor | Low frequency kw | 4.50 | 5.63 | 7.5 | 9.38 | 12 | 9.38 | 9.38 | 15 | 9.38 | 12 | 15 | 12 | 23.5 | 25.5 | 25.5 |
High frequency kw | 13.50 | 16.88 | 22.50 | 28.13 | 36 | 39.38 | 46.88 | 60 | 84.38 | 108 | 135 | 156 | 159.3 | 271.3 | 322.3 | |
Cooling Capacity | Low frequency kw | 22.71 | 28.38 | 37.05 | 47.3 | 60.56 | 47.3 | 47.3 | 75.7 | 47.3 | 60.56 | 75.7 | 60.56 | 103.1 | 103.1 | 103.1 |
High frequency kw | 68.13 | 85.16 | 113.55 | 141.93 | 181.68 | 198.71 | 236.56 | 302.8 | 425.8 | 545.09 | 681.3 | 787.28 | 937 | 1529 | 1825.6 | |
Refrigerant | R410a | |||||||||||||||
Voltage | 3P 380V 50HZ/N/PE | |||||||||||||||
Protection Function | Refrigeration high and low pressure protection, water system fault protection, antifreeze protection, compressor overheating overload protection, etc. | |||||||||||||||
Power For Cooling Water Pump | kw | 3.0 | 3.0 | 4.0 | 4.0 | 4.0 | 5.5 | 5.5 | 7.5 | 7.5 | 11 | 11 | 11 | 18.5 | 22 | 37 |
Chilled Water Flow | m³/h | 15 | 18 | 25 | 30 | 40 | 40 | 50 | 60 | 80 | 100 | 120 | 150 | 185 | 265 | 320 |
Chilled Water Tube | DN | 50 | 50 | 65 | 65 | 80 | 80 | 80 | 100 | 100 | 100 | 125 | 125 | 150 | 200 | 225 |
Water Flow | m³/h | 18 | 22.5 | 30 | 37.5 | 48 | 52.5 | 62.5 | 80 | 110 | 140 | 180 | 200 | 230 | 350 | 450 |
Water Tube Diameter | DN | 50 | 50 | 65 | 65 | 65 | 80 | 80 | 80 | 80 | 125 | 125 | 150 | 150 | 250 | 250 |
Dimension | L | 1800 | 1800 | 2200 | 2200 | 2400 | 2400 | 2400 | 3500 | 3500 | 3500 | 5300 | 5300 | 5300 | 5800 | 6500 |
W | 1200 | 1200 | 1200 | 1200 | 1400 | 1400 | 1400 | 1660 | 1660 | 1660 | 220 | 2200 | 2200 | 2200 | 2350 | |
H | 1300 | 1300 | 1500 | 1500 | 1320 | 1320 | 1320 | 1500 | 1500 | 1500 | 1800 | 1800 | 1800 | 2200 | 2200 | |
Weight | kg | 550 | 550 | 950 | 950 | 1200 | 1200 | 1200 | 1760 | 1950 | 2200 | 2500 | 2500 | 2500 | 3800 | 4200 |